Precision Industrial Instrumentation Ahmedabad, Gujarat • India
Home / Products / Level Instruments / Side Mounted Level Transmitter
Level Instruments

Side Mounted Level Transmitter

Direct-Coupled Side Chamber Continuous Level Measurement

Continuous Liquid Level Monitoring for Tanks & Process Vessels

The FlowDo Side Mounted Level Transmitter is engineered for tanks and process vessels where top-entry access is obstructed, limited by overhead structures, or where side flanged process connections are preferred. It delivers continuous 4–20 mA level feedback with high repeatability and robust mechanical construction.

FlowDo Side Mounted Level Transmitter for continuous industrial liquid level measurement
SIDE MOUNTED Installation
CONTINUOUS LEVEL Measurement
TANKS & VESSELS Application
PROCESS SIGNAL 4–20 mA Output
Product Overview

Continuous Side-Entry Level Sensing

Engineered for tanks with limited top clearance, high overhead piping, or specialized side process nozzles.

The FlowDo Side Mounted Level Transmitter attaches directly to the side of storage tanks or external bypass chambers via ANSI/DIN flanges. Utilizing a precision magnetic float assembly or continuous probe sensor, the instrument follows the liquid interface height and transmits real-time level values without requiring overhead tank access.

This design is particularly advantageous on tall storage silos, indoor vessels with ceiling obstructions, agitating tanks with top mixers, and fuel or chemical tanks with existing side nozzles. The hermetically sealed electronics head outputs an isolated 4–20 mA loop signal for integration into PLC/SCADA systems.

Key Engineering Highlights

  • Direct side nozzle or external chamber mounting eliminates top-access requirements
  • Heavy-duty SS304 / SS316 stainless steel wetted construction
  • Standard 4–20 mA current loop output with optional digital communication
  • Suitable for high operating pressures and temperatures where top seals are difficult
  • IP65/IP66 weatherproof terminal head with dual cable entries
Verified catalogue data

Technical Specifications

Technical parameters for FlowDo Side Mounted Level Transmitters.

Brand / Manufacturer FlowDo Process Instruments
Product Name FlowDo Side Mounted Level Transmitter
Measurement Type Continuous Liquid Level (0–100%)
Mounting Orientation Side Mounted (Horizontal nozzle / external chamber connection)
Measuring Range (Span) 0.2 m to 3.0 m (Direct side probe / chamber length according to tank)
Output Signal Standard 4–20 mA DC (2-Wire Current Loop)
Power Supply 24 V DC (18–32 V DC Loop Powered)
Accuracy ±0.5% of Full Scale
Wetted Materials SS304 / SS316 / SS316L Stainless Steel
Process Connection ANSI 150# / 300# Flanged (1.5", 2", 3", 4") or BSP/NPT Threaded
Operating Temperature -20°C to +120°C (Standard); up to +200°C (High Temp Model)
Operating Pressure Atmospheric up to 16 bar
Enclosure Protection Die-cast Aluminum IP65 / IP66 Weatherproof
Product design

Key Features

Engineered for difficult vessel geometries and demanding industrial installations.

Side Entry Installation

Ideal for vessels with top agitators, cooling coils, limited overhead headroom, or existing side flanged nozzles.

Continuous 4–20 mA Output

Provides complete real-time continuous level values rather than simple high/low on-off switching points.

🛡

Robust SS316 Construction

All wetted components, chambers, and flanges fabricated from heavy-gauge stainless steel for corrosion resistance.

High Pressure & Temp Ratings

Engineered to handle pressurized process tanks up to 16 bar and liquid temperatures up to 200°C.

Weatherproof IP66 Enclosure

Cast aluminum terminal head with dual cable entries and screw terminals for industrial field wiring.

PLC / SCADA Integration

Directly connects to plant PLCs, DCS systems, remote telemetry RTUs, and FlowDo digital indicators.

Industries and processes

Applications

Continuous level monitoring in industrial tanks and vessels across key processing sectors.

Boiler Feedwater & Condensate

Continuous water level monitoring in boiler feed tanks, deaerators, and condensate return vessels.

Hydraulic & Lube Oil Reservoirs

Power plant hydraulic skids, turbine lube oil tanks, and compressor lubrication reservoirs.

Chemical Storage Vessels

Bulk acid and solvent tanks where top nozzle entry is hazardous or structurally constrained.

Water & Effluent Storage

Industrial utility water tanks, cooling tower surge vessels, and ETP neutralization chambers.

Agitated Mixing Tanks

Process vessels with top-mounted mechanical agitators, mixers, and internal heating coils.

OEM Packaged Skids

Compact integration into packaged pump skids, filtration units, and industrial fluid power systems.

System Integration

From Side Chamber to Process Monitoring

Seamless signal transmission from field side-mounted transmitter to central control systems.

Side Mounted Level Transmitter Direct-Coupled Side Chamber Sensor
Continuous Level Value Precision Float / Sensor Interface
4–20 mA Current Loop Standard Industrial Process Signal
Local Indicator FlowDo Level / Process Indicator
PLC / Controller Pump Automation & Alarm Logic
SCADA & Plant Monitoring Real-time telemetry, automated pump interlocks & analytics
Level Technology Overview

Choose the Right Continuous Level Technology

Comparison of primary FlowDo continuous level measurement instruments.

Side Mounted Level Transmitter

Principle
Direct-coupled magnetic float / sensing assembly
Installation
Tank side nozzle / chamber
Process Contact
Sensor wetted assembly in liquid chamber
Best Suited
Compatible tanks with accessible side connections or restricted top access.

Hydrostatic Level Transmitter

Principle
Liquid hydrostatic pressure
Installation
Submerged / pressure sensing
Process Contact
Sensor exposed to liquid
Best Suited
Deep sumps, reservoirs, borewells, and open storage tanks.
View Hydrostatic Transmitter →

Ultrasonic Level Transmitter

Principle
Sound-wave / acoustic echo
Installation
Tank top
Process Contact
Non-contact
Best Suited
Compatible open/closed tanks where ultrasonic conditions are suitable.
View Ultrasonic Transmitter →

Radar Level Transmitter

Principle
Electromagnetic radar / microwave
Installation
Tank top (Flanged / Horn antenna)
Process Contact
Non-contact
Best Suited
Challenging process vessels, storage tanks, and non-contact continuous monitoring.
View Radar Transmitter →

Technology selection should consider medium characteristics, tank geometry, installation access, measurement range, temperature, pressure, atmosphere and required accuracy.

Product Range

Available Level Transmitter Configurations

FlowDo level instruments can be selected according to measurement range, process connection, material compatibility, output and installation requirements.

Catalogue 1 of 2
Related Instrumentation

Related Level Instruments

Explore complementary FlowDo instruments for level measurement, indication and process monitoring.

FlowDo FLD-HLT Hydrostatic Level Transmitter
Level Instruments

Hydrostatic Level Transmitter

Model FLD-HLT Submersible hydrostatic level transmitter for continuous liquid-level measurement in tanks, reservoirs, sumps and open channels.

View details & specs →
FlowDo Ultrasonic Level Transmitter
Level Instruments

Ultrasonic Level Transmitter

Non-contact ultrasonic transmitter for continuous liquid level measurement in tanks, vessels and industrial water applications.

View details & specs →
FlowDo Radar Level Transmitter
Level Instruments

Radar Level Transmitter

Radar-based transmitter for continuous non-contact level measurement in compatible industrial tanks and vessels.

View details & specs →
FlowDo Capacitance Level Transmitter
Level Instruments

Capacitance Level Transmitter

Continuous capacitance-based level measurement for compatible industrial tanks, process liquids and vessels.

View details & specs →
Frequently Asked Questions

Side Mounted Level Transmitter FAQs

Common technical questions regarding side-mounted continuous level measurement.

What is a side mounted level transmitter?

It is an industrial instrument installed on the side nozzle of a tank or external bypass chamber to provide continuous measurement of liquid level (0–100%).

When should side mounting be used instead of top mounting?

Side mounting is ideal when top tank access is restricted by ceiling clearance, agitators, mixers, heating coils, or when tanks have pre-existing side nozzles.

Is it a continuous measurement device?

Yes. A side-mounted transmitter provides continuous 4–20 mA proportional feedback across the calibrated span, unlike a level switch which only detects a single point.

What process connections are available?

Standard ANSI 150#/300# flanged connections (1.5", 2", 3", 4") and heavy-duty threaded process connections according to customer nozzle requirements.

Can it handle high temperatures and pressures?

Yes, stainless steel SS316 wetted construction supports operating pressures up to 16 bar and process temperatures up to 200°C with optional cooling extensions.

Can it connect to PLCs and digital level indicators?

Yes, standard 2-wire 4–20 mA current loop output connects directly to industrial PLCs, DCS systems, SCADA RTUs, and FlowDo digital indicators.

Need Help Selecting a Level Transmitter?

Configure the Right Side Mounted Level Solution for Your Tank

Share your tank dimensions, side nozzle details, liquid medium, temperature, pressure and output requirements with FlowDo to identify a suitable configuration.

For faster selection, provide: Tank Height • Measured Medium • Flange Size/Rating • Temperature • Pressure • Output Requirements

Call Get a Quote